ACCUMAX
The Transmission Line Analyzer from Taurus creates a new platform for transmission line maintenance. This revolutionary new future-proof platform significantly minimizes downtime and overall line maintenance time. The system offers cost-effective monitoring of AC overhead transmission circuits on any de-energized line from 66 kV and above.
The utility of Overhead Offline Fault Analyzer System-ACCUMAX-3
- Commissioning of new Overhead Transmission Line
- Management of Existing Overhead Transmission Line
Now Available on GEM Portal
Application of “Overhead Offline fault analyzer system-ACCUMAX-3” inline pre-commissioning
The ACCUMAX-3 serves as a key application tool in documenting line pre-commissioning tests like
- Line length test
- Continuity test
- Phase Sequence test
- Circuit Verification test
- Line Healthiness test
Application of “Overhead Offline fault analyzer system-ACCUMAX-3” inline Breakdown Maintenance of Existing Transmission lines
The Line Fault Locator unit displays distance of line fault from the testing station/end of the overhead line, with an accuracy of 100 Mtrs. without any input parameter references. The fault locator detects any type of OPEN/SHORT Faults that causes line breakdown
Find the fault – variable time
Fix the fault – fixed time
- Fix the Fault- A necessary fixed time
- Find the Fault-Can also be a fixed component with a huge time reduction
Utility of ACCUMAX-3 in Preventive Management
Line Signature Analysis helps in understanding the developing faults in the line, well in advance by doing serial comparison Line signature data, so that remedial action can be taken before the line breaks down.
“Overhead Offline Fault Analyzer System-ACCUMAX-3 being an auto-calibrated portable system is useful in monitoring & analyzing of critical line condition and performance parameters which includes all types of faults,line healthiness. Line component data is analyzed to optimize asset utilization and to improve system reliability and quality of supply.
Utility of ACCUMAX-3 in Fault Finding
Line Signature Analysis helps in identifying some of the developing problems in a transmission line listed below by serial comparison of LSA’s
- Conductor corrosion
Broken inner/outer conductors - Lightning strike conductor damage
- Loose joints
- The major error in support structures
- The extra sag of lines
- Encroachment into a right of way
Features
Fault & line diagnostics
Flexibility in utility and application
Auto calibrated system
Direct reading digital display
Line signature Analysis
Zoom blanking
Direct PC storage
TADMA Software
Applications
- Offline Fault Location
- Power Line continuity test
- Power line Phase sequence tests
- Line Signature Analysis study for the entire length of the Power line
- All types of faults & inhomogeneity in the line is located Fault resolution: +/- 100 meters
- Commissioning of new Overhead Power Lines
- Virtual Line Patrolling
- Prediction of inhomogeneous points in the Power line
Technical Specifications
- Capable of injecting a High test voltage & High Frequency in the transmission line for appropriate performance.
- Capable of locating inhomogeneous points on power lines from 66KV to 800 kV lines in selectable versions.
- Types of Fault detection a. Open fault b. Short fault change to Short c. Line to line fault d. De capping fault e. Inhomogeneous points f. Indicate faults on the spur lines
- 3-Phase Simultaneously – All the three phases to be detected and measured together.
- Fault resolution - +/- 100 meters throughout the range of 1000 kilometers.
- The test kit is compatible for EMI/EMC/safety environment requirement as per IEC.
- Preloaded operating MS Window 7 professional or better with latest version of application software required for storage analysis and record management.