MAX 3
The TAURUS overhead Power Line Fault Analyzer System is a precise fault locating tool for HV, EHV, UHV Main lines and Spur lines with extended applications of line healthiness study, pre-charging and pre-commissioning checks.
The Power Line Fault Analyzer precisely detects all types of faults and is an important tool that can save enormous time and revenue for transmission and distribution utilities.
Now Available on GEM Portal
Features
Fault & line diagnostics
Fault information and distance to fault in direct reading , digital data display in km, a comprehensive line signature Analysis and diagnosis.
Flexibility in utility and application
Portable system that can be used on any de-energized line from 66kv to 800kV AC lines. *Upgradeable to Match for 1200kV Lines
Auto calibrated system
Auto calibrated system- Requires no input parameter or pre-setting. Extremely simple operation
Direct reading digital display
No interpretation required.
Line signature Analysis
Reveals all the inhomogeneity prevalent along the transmission line. Serial comparison of this data enables the user to infer deteriorating points along the line which could be the cause of power loss, frequent tripping and eventual line breakdown.
Zoom blanking
Unique capability to easily detect faults in spur lines and other applications with extended range blanking facility.
Direct PC storage
No cumbersome interfacing modules to storage units, Review and print only selected frames/ data.
TADMA Software
Using TADMA, the faults and inhomogeneties of the line are automatically tabulated and stored. TADMA instantaneously computes, documents, classifies and interprets Line Signature study.
Applications
- Offline Fault Location
- Power Line continuity test
- Power line Phase sequence tests
- Line Signature Analysis study for the entire length of the Power line
- Commissioning of new Overhead Power Lines
- Virtual Line Patrolling
- Prediction of inhomogeneous points in the Power line
- All types of faults & inhomogeneity in the line is located accurately with a resolution of +/- 100 Mtrs within a very short period of time
Technical Specifications
- Capable of injecting a High test voltage & High Frequency in the transmission line for appropriate performance.
- Capable of locating inhomogeneous points on power lines from 66KV to 800 kV lines in selectable versions.
- Types of Fault detection a. Open fault b. Short fault change to Short c. Line to line fault d. De capping fault e. Inhomogeneous points f. Indicate faults on the spur lines
- Available in 2000 / 1000 / 100 Kms versions.
- 3-Phase Simultaneously – All the three phases to be detected and measured together.
- Fault resolution - +/- 100 meters throughout the range of 1000 kilometers.
- Preloaded operating MS Window 7 professional or better with latest version of application software required for storage analysis and record management.