MAX SLS
The TAURUS overhead Power Line Fault Analyzer System is designed & developed to be utilized as a precise fault locating tool for HV, EHV Main lines and Spur lines with extended applications of line healthiness study, pre-charging and pre-commissioning checks.
The Power Line Fault Analyzer precisely detects all types of open & short faults that causes Line breakdown. AN IMPOTANT TOOL FOR ACCURATE FAULT FINDING IN 33KV TO 220KV POWER LINES UP TO A DISTANCE OF 300KMS
This can be achieved through this facilities:
- Enhanced life of the deployed power lines
- Identify any fault during commissioning and trips
- The deployment of Distribution during disaster management situations
AN IMPORTANT TOOL FOR ACCURATE FAULT FINDING IN 33KV TO 220KV POWER LINES UP TO A DISTANCE OF 300KMS
Now Available on GEM Portal
Features
Fault & line diagnostics
Fault information and distance to fault in direct reading, digital data display in kms and a comprehensive line signature Analysis and diagnosis.
Flexibility in utility and application
Portable system that can be used on any de-energized line from 33kv to 220kV power lines. for a distance less than 300Kms
Auto calibrated system
Auto calibrated system- Requires no input parameter or pre-setting. Extremely simple operation
Direct reading digital display
No interpretation required.
Line signature Analysis
Reveals all the inhomogeneity prevalent along the transmission line. Serial comparison of this data enables the user to infer deteriorating points along the line which could be the cause of power loss, frequent tripping and eventual line breakdown.
Zoom blanking
Unique capability to easily detect faults in spur lines and other applications with extended range blanking facility.
Direct PC storage
No cumbersome interfacing modules to storage units, Review and print only selected frames/ data.
TADMA Software
Using TADMA, Line Signature Analysis and its inhomogeneties are automatically tabulated and printed / stored. TADMA instantaneously computes, documents, initiated its diagnostic s/w, classifies and interprets LSA line study. Customized reference to each & every line including tower schedules (opt).
Applications
- Offline Fault Location
- Power Line continuity test
- Power line Phase sequence tests
- Line Signature Analysis study for the entire length of the Power line
- Commissioning of new Overhead Power Lines
- Virtual Line Patrolling
- Prediction of inhomogeneous points in the Power line
- All types of faults & inhomogeneity in the line is located accurately with a resolution of +/- 100 Mtrs within a very short period of time
Technical Specifications
- Capable of injecting a High test voltage & High Frequency in the transmission line for appropriate performance.
- Capable of locating inhomogeneous points on power lines from 33KV to 220 kV power lines in selectable versions.
- Types of Fault detection a. Open fault b. Short fault change to Short c. Line to line fault d. De capping fault e. Inhomogeneous points f. Indicate faults on the spur lines
- Available in 2000 / 1000 / 100 Kms versions.
- 3-Phase Simultaneously – All the three phases to be detected and measured together.
- Fault resolution - +/- 100 meters throughout the range of 300 kilometers. Preloaded operating MS Window 10 professional or better with latest version of application software required for storage analysis and record management.
- Preloaded operating MS Window 7 professional or better with latest version of application software required for storage analysis and record management.